Open the file the microscope wrote. What the file holds decides where it opens.
Open a file with Open Image… (⌘O) or from File › Open Recent. The same command opens every kind of file, not only images.
What opens
| Kind of data | Formats | Opens in |
|---|---|---|
| TEM images | DigitalMicrograph .dm3 and .dm4, Velox .emd, TIFF, MRC |
Imaging |
| SEM images | TIFF from Thermo Fisher (FEI), Zeiss and Tescan, read with the microscope's settings; JEOL .img and .map |
Imaging |
| TEM spectrum images | EDS from Velox and GMS, EELS from GMS, single .msa spectra |
Spectroscopy |
| SEM-EDS | Bruker .bcf and .spx; EDAX .spd, .lsd and .spc; JEOL .pts, .eds and .asw; a single spectrum in a HyperSpy .hspy file |
Spectroscopy |
| EBSD and TKD patterns | h5ebsd from kikuchipy, Bruker, EDAX and Oxford Instruments (.h5oina); EDAX .up1 and .up2; Oxford .ebsp; NORDIF Pattern.dat |
EBSD › Patterns |
| Orientation maps | .ang, .ctf, Oxford .h5oina saved without patterns, .h5 maps from orix, Bruker Esprit and EDAX OIM saved without patterns, EMsoft's dictionary indexing |
EBSD › Maps |
A diffraction pattern is an image file; open it and go to the Diffraction workspace.
TKD patterns are read and indexed as EBSD patterns are. No TKD dataset has been checked in the app yet.
Files that are read together
Some files are read together with a file of the same name beside them. Keep them in one folder:
| You open | The app also reads |
|---|---|
EDAX .spd or .lsd |
the .spc of the same name |
EDAX .up1 or .up2 |
the .ang of the same name |
Oxford .ebsp |
the .ctf of the same name |
NORDIF Pattern.dat |
Setting.txt and the background pattern in its folder |
For a NORDIF scan the app asks for the folder the first time, because macOS gives it only the file you picked. Choose the folder and click Allow; the app remembers it.
JEOL .asw projects
A JEOL .asw project names other files. The app is not given access to those yet, so a project may not open. Open the .pts or .eds file itself.
Calibration from the file
The app reads the pixel size, and for SEM images the microscope's settings, from the file. The Calibration section of the Image inspector shows the pixel size and the field it came from. When the file carries none, the image is marked "Not calibrated" and lengths are given in pixels.
For an SEM image with a databar, Settings › Images › Hide the SEM databar crops the bar from the picture.
When a file is not read
The app does not guess. A file it cannot read is listed with "Can't read" and the reason, or an alert says why it cannot be opened. Troubleshooting lists the usual cases.